{"id":7,"date":"2026-11-16T05:43:41","date_gmt":"2026-11-16T05:43:41","guid":{"rendered":"https:\/\/www.surakchha.com\/blog\/?p=7"},"modified":"2026-11-16T05:43:41","modified_gmt":"2026-11-16T05:43:41","slug":"how-to-choose-the-right-fire-extinguisher-for-your-office-or-factory","status":"publish","type":"post","link":"https:\/\/www.surakchha.com\/blog\/fire-safety-tips\/how-to-choose-the-right-fire-extinguisher-for-your-office-or-factory\/","title":{"rendered":"How to Choose the Right Fire Extinguisher for Your Office or Factory"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Selecting the right fire extinguisher is not just a compliance requirement \u2014 it is the difference between containing a small fire and losing an entire building. Indian fire safety regulations under IS 2190 mandate that every commercial, industrial and residential building must have appropriate fire extinguishers installed and maintained. This guide explains the different types of fire extinguishers available in India, which one suits your specific environment, and what sizes you need.<\/p>\n\n\n\n<h2 class=\"wp-block-heading is-style-default\">Understanding Fire Classes in India<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Fire extinguishers are classified based on the type of fire they can handle. In India, fires are categorised into five classes as per IS 15683:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Class A: Solid material fires \u2014 wood, paper, cloth, plastic, rubber<br>Class B: Flammable liquid fires \u2014 petrol, diesel, oil, paint, solvents<br>Class C: Flammable gas fires \u2014 LPG, CNG, propane, acetylene<br>Class D: Metal fires \u2014 magnesium, sodium, aluminium (industrial only)<br>Class E: Electrical fires \u2014 live electrical equipment, server rooms, control panels<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Types of Fire Extinguishers<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.surakchha.com\/fire-ex.html\">ABC \/ DCP (Dry Chemical Powder)<\/a> Fire Extinguisher<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">ABC extinguishers are the most versatile and commonly used in India. They contain mono ammonium phosphate powder that works on Class A, B and C fires, and is safe for electrical fires. This is the best general-purpose extinguisher for offices, shops, schools, hospitals and homes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Available sizes: 1kg, 2kg, 4kg, 6kg, 9kg, 25kg, 50kg, 75kg<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.surakchha.com\/fire-co2.html\">CO2 (Carbon Dioxide)<\/a> Fire Extinguisher<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">CO2 extinguishers are ideal for electrical fires (Class E) and flammable liquid fires (Class B). They leave no residue, making them perfect for server rooms, electrical panels, laboratories, and areas with sensitive electronics. CO2 displaces oxygen and cools the fire without damaging equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Available sizes: 2kg, 3kg, 4.5kg, 6.5kg, 9kg<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mechanical Foam Fire Extinguisher<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Foam extinguishers are effective on Class A and B fires. They create a smothering foam blanket that cuts off oxygen and prevents re-ignition. Best for petrol pumps, paint shops, chemical storage areas, and kitchens using oil.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Available sizes: 9 litres, 50 litres<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Water (CO2 Type) Fire Extinguisher<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Water extinguishers are for Class A fires only \u2014 solid combustible materials like wood, paper and cloth. They work by cooling the burning material rapidly. Not suitable for electrical or liquid fires. Constructed as per IS 940.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Available sizes: 9 litres, 50 litres<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Which Fire Extinguisher is Right for Your Business?<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">For Offices and Commercial Buildings<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">ABC (DCP) extinguisher is the primary choice. A 4kg or 6kg ABC unit at every exit point and near electrical panels. For server rooms and IT infrastructure, add CO2 extinguishers alongside ABC.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">For Factories and Warehouses<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">9kg ABC extinguishers placed every 15 metres of floor area. For areas with flammable liquids (paint storage, fuel areas), add foam extinguishers. For large industrial spaces, 25kg or 50kg trolley-mounted units are recommended.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">For Hotels and Restaurants<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">ABC extinguishers in guest rooms and corridors. Foam extinguishers in kitchens. CO2 extinguishers near electrical installations.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">For Server Rooms and Data Centres<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">CO2 extinguishers only. Never use water or foam near live electrical equipment. ABC can be used as backup but CO2 is preferred because it leaves no residue on sensitive electronics.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">For Petrol Pumps and Chemical Storage<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Foam extinguishers for liquid fires. ABC extinguishers for general areas. CO2 for electrical panels.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">For Schools and Hospitals<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">4kg or 6kg ABC extinguishers at every exit and corridor junction. Easy to operate for non-technical staff.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Many Fire Extinguishers Do You Need?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">As per IS 2190, the general guidelines are:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>One 9kg ABC extinguisher per 100 square metres of floor area for light hazard occupancies (offices, schools)<\/li>\n\n\n\n<li>One 9kg ABC extinguisher per 50 square metres for medium hazard (factories, warehouses)<\/li>\n\n\n\n<li>One 9kg ABC extinguisher per 25 square metres for high hazard (chemical plants, fuel storage)<\/li>\n\n\n\n<li>Minimum 2 extinguishers per floor regardless of area<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Your local fire department may have additional requirements. Surakchha offers free on-site inspection to assess your exact requirements. Call 0562-4003732.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Fire Extinguisher Price in India<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Prices vary by type, size and brand:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ABC \/ DCP: Rs. 500 (1kg) to Rs. 8,000+ (25kg)<br>CO2: Rs. 3,500 (4.5kg) to Rs. 15,000+ (9kg)<br>Foam: Rs. 2,000 (9L) to Rs. 12,000+ (50L)<br>Water: Rs. 1,500 (9L) to Rs. 10,000+ (50L)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">All extinguishers supplied by Surakchha are ISI-certified from approved manufacturers. Bulk discounts available for factories, builders and government departments.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Maintenance and Compliance<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Installing fire extinguishers is only the first step. IS 2190 requires:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Monthly: Visual inspection by your staff \u2014 check pressure gauge is in green zone, safety pin intact, no visible damage<br>Annually: Professional service by a certified technician \u2014 internal inspection, refilling if needed<br>Every 5 years: <a href=\"https:\/\/www.surakchha.com\/hydrotesting-Extenguisher.html\">Hydrostatic pressure testing (hydrotesting)<\/a> for ABC\/DCP cylinders<br>Every 3 years: Hydrotesting for CO2 cylinders as per IS 307<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Failure to maintain records can result in fire NOC cancellation and insurance claim rejection. Surakchha provides <a href=\"https:\/\/www.surakchha.com\/contactus.php\">Annual Maintenance Contracts (AMC)<\/a> covering all servicing, refilling and hydrotesting. We maintain compliance records for you.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why Choose <a href=\"https:\/\/www.surakchha.com\/index.html\">Surakchha<\/a>?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">20+ years of experience in fire safety equipment supply and servicing<br>ISI-certified products from trusted manufacturers<br>Trusted by SAIL, GAIL, CONCOR, Pacific Mall and Allahabad Bank<br>Complete service \u2014 supply, refilling, hydrotesting, AMC and fire NOC assistance<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Contact Us<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Call: +91-9411411587, 0562-4003732<br>Email: <a href=\"mailto:enquiry@surakchha.net\">enquiry@surakchha.net<\/a><br>WhatsApp: +91-9411411587<br>Website: <a href=\"http:\/\/www.surakchha.com\">www.surakchha.com<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Selecting the right fire extinguisher is not just a compliance requirement \u2014 it is the difference between containing a small fire and losing an entire building. Indian fire safety regulations under IS 2190 mandate that every commercial, industrial and residential building must have appropriate fire extinguishers installed and maintained. This guide explains the different types [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":10,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3],"tags":[],"class_list":["post-7","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-fire-safety-tips"],"_links":{"self":[{"href":"https:\/\/www.surakchha.com\/blog\/wp-json\/wp\/v2\/posts\/7","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.surakchha.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.surakchha.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.surakchha.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.surakchha.com\/blog\/wp-json\/wp\/v2\/comments?post=7"}],"version-history":[{"count":2,"href":"https:\/\/www.surakchha.com\/blog\/wp-json\/wp\/v2\/posts\/7\/revisions"}],"predecessor-version":[{"id":11,"href":"https:\/\/www.surakchha.com\/blog\/wp-json\/wp\/v2\/posts\/7\/revisions\/11"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.surakchha.com\/blog\/wp-json\/wp\/v2\/media\/10"}],"wp:attachment":[{"href":"https:\/\/www.surakchha.com\/blog\/wp-json\/wp\/v2\/media?parent=7"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.surakchha.com\/blog\/wp-json\/wp\/v2\/categories?post=7"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.surakchha.com\/blog\/wp-json\/wp\/v2\/tags?post=7"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}